Testing
S & N Pump Co. provides full scale in-house performance testing on new and existing equipment. Performance testing establishes field condition and ensures equipment meets its operational requirements.
Test Cell #1
Physical Capabilities
- 13 Ft. Pit Depth
- 26 inch (25.75" I.D.) Casing 2, 3, and 8 inch ANSI Connections
- Digital Signet Flow Meters registering in U.S. Gallons Per Minute (GPM) and Pounds per Square Inch (PSI)
- Test Codes per HI, AWWA, ANSI, and ASME-PTC.
- All equipment calibration is traceable to National Bureau of Standards
Performance Capabilities
- Performance Testing
- Flows up to 1,500 GPM
- Pressures up to 300 Pounds PSI
- Test Voltages:
- 1 Phase 115 V
- 1 Phase 230 V
- 3 Phase 230 V
- 3 Phase 460 V
- HP up to 125 HP
Test Cell #2
Physical Capabilities
- 50 Ft. Pit Depth
- 60 inch Casing
- Ultrasonic Doppler Flow Meter and Digital Flow Meter
- Test Codes per HI, AWWA, ANSI, ans ASME-PTC.
- All equipment calibration is traceable to National Bureau of Standards
Performance Capabilities
- Performance or NPSH Testing-Complete or Partial Assembled Unit Testing Available
- Flows up to 10,000 GPM
- Pressures up to 300 Pounds PSI
- Test Voltages:
- 3 Phase 460 V
- 3 Phase 575 V
- 3 Phase 4160 V
- HP to 750 HP
*Other test voltages are available via the use of rental generators*