Testing

S & N Pump Co. provides full scale in-house performance testing on new and existing equipment. Performance testing establishes field condition and ensures equipment meets its operational requirements.

Test Cell #1

  • Test Pit #1 Testing Submersible PumpTest Pit #1 Testing Submersible PumpElectric Submersible
  • Test Pit #1 Testing Submersible PumpTest Pit #1 Testing Submersible PumpElectric Submersible










Physical Capabilities

  • 13 Ft. Pit Depth
  • 26 inch (25.75" I.D.) Casing 2, 3, and 8 inch ANSI Connections
  • Digital Signet Flow Meters registering in U.S. Gallons Per Minute (GPM) and Pounds per Square Inch (PSI)
  • Test Codes per HI, AWWA, ANSI, and ASME-PTC.
  • All equipment calibration is traceable to National Bureau of Standards

Performance Capabilities

  • Performance Testing
  • Flows up to 1,500 GPM
  • Pressures up to 300 Pounds PSI
  • Test Voltages:
    • 1 Phase 115 V
    • 1 Phase 230 V
    • 3 Phase 230 V
    • 3 Phase 460 V
    • HP up to 125 HP


Test Cell #2

  • Test Pit #2 Testing Vertical Turbine PumpVertical Turbine
  • Test Pit #2 Testing Vertical Turbine PumpVertical Turbine










Physical Capabilities

  • 50 Ft. Pit Depth
  • 60 inch Casing
  • Ultrasonic Doppler Flow Meter and Digital Flow Meter
  • Test Codes per HI, AWWA, ANSI, ans ASME-PTC.
  • All equipment calibration is traceable to National Bureau of Standards

Performance Capabilities

  • Performance or NPSH Testing-Complete or Partial Assembled Unit Testing Available
  • Flows up to 10,000 GPM
  • Pressures up to 300 Pounds PSI
  • Test Voltages:
    • 3 Phase 460 V
    • 3 Phase 575 V
    • 3 Phase 4160 V
    • HP to 750 HP


*Other test voltages are available via the use of rental generators*